TY - JOUR
T1 - Use of pressurized liquid extraction (PLE)/gas chromatography-electron capture detection (GC-ECD) for the determination of biodegradation intermediates of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in soils
AU - Zhang, Baohong
AU - Pan, Xiaoping
AU - Cobb, George P.
AU - Anderson, Todd A.
N1 - Funding Information:
This research was partially supported by the U.S. Department of Defense contract CU1141, through the Strategic Environmental Research and Development Program (SERDP) under a Cooperative Agreement IERA-99-001 with the USAF, Institute of Environment, Safety, and Occupational Health, Brooks AFB, TX.
PY - 2005/9/25
Y1 - 2005/9/25
N2 - A rapid, sensitive, and reproducible method was developed for quantitative determination of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and its biodegradation intermediates, hexahydro-1-nitroso-3,5-dinitro-1,3,5-triazine (MNX), hexahydro-1,3-dinitroso-5-nitro-1,3,5-triazine (DNX), and hexahydro-1,3,5-trinitroso-1,3,5-triazine (TNX) in soils. RDX, MNX, DNX, or TNX was extracted from soil by pressurized liquid extraction (PLE), followed by cleanup using florisil. Instrumental analysis was performed using gas chromatography with electron capture detection (GC-ECD), which was highly sensitive to the parent explosive and its metabolites. The method detection limits (MDLs) were 0.243, 0.095, 0.138, and 0.057 ng/g for RDX, MNX, DNX, and TNX, respectively. The method gave high recovery (98-102%), good precision (0.22-5.14%), and reproducibility, and proved to be suitable for real world sample analysis.
AB - A rapid, sensitive, and reproducible method was developed for quantitative determination of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and its biodegradation intermediates, hexahydro-1-nitroso-3,5-dinitro-1,3,5-triazine (MNX), hexahydro-1,3-dinitroso-5-nitro-1,3,5-triazine (DNX), and hexahydro-1,3,5-trinitroso-1,3,5-triazine (TNX) in soils. RDX, MNX, DNX, or TNX was extracted from soil by pressurized liquid extraction (PLE), followed by cleanup using florisil. Instrumental analysis was performed using gas chromatography with electron capture detection (GC-ECD), which was highly sensitive to the parent explosive and its metabolites. The method detection limits (MDLs) were 0.243, 0.095, 0.138, and 0.057 ng/g for RDX, MNX, DNX, and TNX, respectively. The method gave high recovery (98-102%), good precision (0.22-5.14%), and reproducibility, and proved to be suitable for real world sample analysis.
KW - Electron capture detection (ECD)
KW - Explosives
KW - Gas chromatography (GC)
KW - Pressurized liquid extraction (PLE)
KW - RDX
KW - Soil analysis
UR - http://www.scopus.com/inward/record.url?scp=24044496551&partnerID=8YFLogxK
U2 - 10.1016/j.jchromb.2005.07.046
DO - 10.1016/j.jchromb.2005.07.046
M3 - Article
C2 - 16112625
AN - SCOPUS:24044496551
SN - 1570-0232
VL - 824
SP - 277
EP - 282
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 1-2
ER -