TY - JOUR
T1 - The SMART (small mass, affordable, rapid, transfer-less) digestion method for heavy metal determinations
AU - French, Amanda D.
AU - Ashbaugh, Hannah M.
AU - Steinmetz, Gary
AU - Barnes, Melanie
AU - Conway, Warren
AU - Klein, David
N1 - Publisher Copyright:
© 2017 Informa UK Limited, trading as Taylor & Francis Group.
PY - 2017/5/3
Y1 - 2017/5/3
N2 - The S.M.A.R.T. (small mass, affordable, rapid, transfer-less) digestion method was developed to determine heavy metal concentrations in small sample masses. The S.M.A.R.T. digestion method is a hot water bath digestion where sample digestion and dilution are performed in the original sample tube. This method is faster than the typical methods used and reduces potential sources of error. Masses as small as 0.01 g have been digested and analysed using this method. The preparation and digestion time is reduced from 10 h to less than 4 h. Acid volumes are reduced from millilitres to microlitres and the only disposable supplies needed are sample tubes and pipette tips. Method accuracy was determined by digesting seven replicates of two standard reference materials using the S.M.A.R.T. method and analysing samples by inductively coupled plasma mass spectrometry. The S.M.A.R.T. digestion method was found to provide excellent recoveries for Al (76 ± 2.7%), Mn (99 ± 11%), Co (92 ± 17%), Ni (93 ± 28%), Cu (109 ± 33%), Zn (97 ± 7.1%), As (108 ± 20%), Sr (90 ± 12%), Mo (84 ± 23%), Ag (91 ± 1.8%), Cd (95 ± 6.2%), Sn (139 ± 52%) and Pb (95 ± 22%). This study has successfully developed an efficient and reproducible digestion method for heavy metal determination in limited biomass samples.
AB - The S.M.A.R.T. (small mass, affordable, rapid, transfer-less) digestion method was developed to determine heavy metal concentrations in small sample masses. The S.M.A.R.T. digestion method is a hot water bath digestion where sample digestion and dilution are performed in the original sample tube. This method is faster than the typical methods used and reduces potential sources of error. Masses as small as 0.01 g have been digested and analysed using this method. The preparation and digestion time is reduced from 10 h to less than 4 h. Acid volumes are reduced from millilitres to microlitres and the only disposable supplies needed are sample tubes and pipette tips. Method accuracy was determined by digesting seven replicates of two standard reference materials using the S.M.A.R.T. method and analysing samples by inductively coupled plasma mass spectrometry. The S.M.A.R.T. digestion method was found to provide excellent recoveries for Al (76 ± 2.7%), Mn (99 ± 11%), Co (92 ± 17%), Ni (93 ± 28%), Cu (109 ± 33%), Zn (97 ± 7.1%), As (108 ± 20%), Sr (90 ± 12%), Mo (84 ± 23%), Ag (91 ± 1.8%), Cd (95 ± 6.2%), Sn (139 ± 52%) and Pb (95 ± 22%). This study has successfully developed an efficient and reproducible digestion method for heavy metal determination in limited biomass samples.
KW - Small mass
KW - acid digestion
KW - environmental
KW - heavy metals
UR - http://www.scopus.com/inward/record.url?scp=85019182021&partnerID=8YFLogxK
U2 - 10.1080/03067319.2017.1328060
DO - 10.1080/03067319.2017.1328060
M3 - Article
SN - 0306-7319
VL - 97
SP - 499
EP - 507
JO - International Journal of Environmental Analytical Chemistry
JF - International Journal of Environmental Analytical Chemistry
IS - 6
ER -