The effect of dead-timeless silicon strip readout at CDF II

A. Affolder, M. Garcia-Sciveres, J. Goldstein, C. Hill, D. Stuart, I. Volobouev

Research output: Contribution to journalArticle

Abstract

The Run IIa CDF Silicon Upgrade has recently finished installation. The detector uses revision D of the SVX3 readout IC. This final revision incorporated new features in order to improve the potential of dead-timeless operation. This paper describes measurements of dead-timeless effects on silicon strip readout on the test bench. This paper also describes tests of the dynamic pedestal subtraction circuitry, which is shown to improve greatly the dead-timeless performance of the silicon systems.

Original languageEnglish
Pages (from-to)197-200
Number of pages4
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume501
Issue number1
DOIs
StatePublished - Mar 21 2003

Keywords

  • Dead-timeless
  • Pedestal subtraction
  • SVX3D
  • Silicon strip

Fingerprint Dive into the research topics of 'The effect of dead-timeless silicon strip readout at CDF II'. Together they form a unique fingerprint.