T1 - Stability analysis and fail-safe operation of inverters operated in parallel
AU - Konstantopoulos, George C.
AU - Zhong, Qing Chang
AU - Ren, Beibei
AU - Krstic, Miroslav
N1 - Publisher Copyright:
© 2015 Taylor and Francis.
PY - 2015/7/3
Y1 - 2015/7/3
N2 - In this paper, the stability in the sense of boundedness of inverters operated in parallel is proven and the fail-safe operation is achieved for generic linear or nonlinear loads described in the generalised dissipative Hamiltonian form. The robust droop controller (RDC), recently proposed in the literature for achieving accurate proportional power sharing and tight voltage regulation, is implemented in a nonlinear matrix form to achieve a bounded inverter voltage and inherit a fail-safe capability. Using nonlinear Lyapunov methods, it is proven that the RDC with fail-safe approximates the original RDC, generates a bounded inverter output voltage within the given technical limits and guarantees nonlinear closed-loop system stability in the sense of boundedness. When the prescribed limits are violated, e.g. due to sensor failure, the proposed method rapidly shuts down in a continuous-time manner, thus disconnecting the inverter to prevent a complete system failure even when the protection circuit fails. Extensive simulation results are presented to demonstrate this approach for two single-phase paralleled inverters feeding a linear and a nonlinear load under a sensor failure scenario.
AB - In this paper, the stability in the sense of boundedness of inverters operated in parallel is proven and the fail-safe operation is achieved for generic linear or nonlinear loads described in the generalised dissipative Hamiltonian form. The robust droop controller (RDC), recently proposed in the literature for achieving accurate proportional power sharing and tight voltage regulation, is implemented in a nonlinear matrix form to achieve a bounded inverter voltage and inherit a fail-safe capability. Using nonlinear Lyapunov methods, it is proven that the RDC with fail-safe approximates the original RDC, generates a bounded inverter output voltage within the given technical limits and guarantees nonlinear closed-loop system stability in the sense of boundedness. When the prescribed limits are violated, e.g. due to sensor failure, the proposed method rapidly shuts down in a continuous-time manner, thus disconnecting the inverter to prevent a complete system failure even when the protection circuit fails. Extensive simulation results are presented to demonstrate this approach for two single-phase paralleled inverters feeding a linear and a nonlinear load under a sensor failure scenario.
KW - fail-safe operation
KW - nonlinear systems
KW - parallel operation of inverters
KW - proportional load sharing
KW - stability
UR - http://www.scopus.com/inward/record.url?scp=84930764707&partnerID=8YFLogxK
U2 - 10.1080/00207179.2015.1041553
DO - 10.1080/00207179.2015.1041553
M3 - Article
AN - SCOPUS:84930764707
SN - 0020-7179
VL - 88
SP - 1410
EP - 1421
JO - International Journal of Control
JF - International Journal of Control
IS - 7
ER -