Microscopic analysis for water stressed by high electric fields in the prebreakdown regime

R. P. Joshi, J. Qian, K. H. Schoenbach, E. Schamiloglu

Research output: Contribution to journalArticle

40 Scopus citations

Abstract

The electrical double layer at the electrode-water interface for high-voltage devices close to the breakdown point was analyzed. The study was carried out based on a static, Monte Carlo approach. It was found that large pressures associated with the Maxwell stress tensor would be created at the electrode boundaries. the results show that the strong dipole realignment, ion-ion correlation and finite-size effects can modify the electric fields and local permittivity at the electrode interface.

Original languageEnglish
Pages (from-to)3617-3625
Number of pages9
JournalJournal of Applied Physics
Volume96
Issue number7
DOIs
StatePublished - Oct 1 2004

Fingerprint Dive into the research topics of 'Microscopic analysis for water stressed by high electric fields in the prebreakdown regime'. Together they form a unique fingerprint.