N2 - To simulate space cooling or drying systems for various geographical regions (low, moderate, and high humidity regions) a liquid desiccant system consisting of a humidifier and dehumidifier has been designed and constructed. This system consists of two coupled humidifying and dehumidifying packed columns filled with plastic Intalox Snowflake packing material. Experimental measurements of the dehumidifier performance utilizing a new cost effective liquid desiccant mixture (CELD), total desiccant salt content 40% wt to 45% wt (salt comprised of equal portions by weight of lithium chloride and calcium chloride), have been carried out. The effect of different independent variables such as packing height, air inlet temperature and humidity ratio, and liquid desiccant inlet temperature, flow rate and concentration on the performance of the dehumidifier has been investigated. Experimental results demonstrate that the CELD is a promising desiccant for cooling and drying operations.
AB - To simulate space cooling or drying systems for various geographical regions (low, moderate, and high humidity regions) a liquid desiccant system consisting of a humidifier and dehumidifier has been designed and constructed. This system consists of two coupled humidifying and dehumidifying packed columns filled with plastic Intalox Snowflake packing material. Experimental measurements of the dehumidifier performance utilizing a new cost effective liquid desiccant mixture (CELD), total desiccant salt content 40% wt to 45% wt (salt comprised of equal portions by weight of lithium chloride and calcium chloride), have been carried out. The effect of different independent variables such as packing height, air inlet temperature and humidity ratio, and liquid desiccant inlet temperature, flow rate and concentration on the performance of the dehumidifier has been investigated. Experimental results demonstrate that the CELD is a promising desiccant for cooling and drying operations.
UR - http://www.scopus.com/inward/record.url?scp=0026971098&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:0026971098
SN - 0791810526
T3 - American Society of Mechanical Engineers, Heat Transfer Division, (Publication) HTD
SP - 1
EP - 8
BT - General Papers in Heat Transfer and Heat Transfer in Hazardous Waste Processing
PB - Publ by ASME
T2 - Winter Annual Meeting of the American Society of Mechanical Engineers
Y2 - 8 November 1992 through 13 November 1992
ER -