Application of microwave 3D SAR imaging technique for evaluation of corrosion in steel rebars embedded in cement-based structures

S. Kharkovsky, J. T. Case, M. T. Ghasr, R. Zoughi, S. W. Bae, A. Belarbi

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

19 Scopus citations

Abstract

This paper presents and discusses the attributes and results of using wideband microwave 3D SAR-based imaging technique for evaluation of reinforced cement-based structures. The technique was used to detect corrosion and thinning of reinforcing steel bars and its potential was demonstrated through experiments for different bar sizes, depth of rebar locations, and spacing between rebars. The results of a limited and preliminary investigation in which thinning of rebars with and without rust in two mortar samples were obtained at three frequency bands covering the frequency range from 8.2 GHz-26.5 GHz.

Original languageEnglish
Title of host publicationReview of Progress in Quantitative Nondestructive Evaluation
Pages1516-1523
Number of pages8
Edition31
DOIs
StatePublished - 2012
Event38th Annual Review of Progress in Quantitative Nondestructive Evaluation, QNDE - Burlington, VT, United States
Duration: Jul 17 2011Jul 22 2011

Publication series

NameAIP Conference Proceedings
Number31
Volume1430
ISSN (Print)0094-243X
ISSN (Electronic)1551-7616

Conference

Conference38th Annual Review of Progress in Quantitative Nondestructive Evaluation, QNDE
CountryUnited States
CityBurlington, VT
Period07/17/1107/22/11

Keywords

  • 3D Images
  • Cement-Based Structures
  • Corrosion
  • Microwaves
  • SAR
  • Steel Rebars