Accuracy and precision of U-Pb zircon geochronology at high spatial resolution (7-20 μm spots) by laser ablation-ICP-single-collector-sector-field-mass spectrometry

Pulok K. Mukherjee, A. Kate Souders, Paul J. Sylvester

Research output: Contribution to journalArticlepeer-review

24 Scopus citations

Abstract

Use of small spots (≤20 μm) for laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) U-Pb zircon geochronology is of increasing interest in the Earth sciences because the temporal record of geologic processes is often preserved on a fine scale within zircon grains. However, the systematic biases and external sources of uncertainty of U-Pb ages is poorly defined when measured on small spots by LA-ICP-single-collector-sector-field (SF)-MS instrumentation. This study addresses the accuracy and precision for small spots and specifically the extent to which short ablation times limit Pb/U Down-Hole Fractionation (DHF), which largely controls the accuracy of the U-Pb ages. Six zircon reference materials (91500, FC-1, R33, Temora 2, Plešovice, and Fish Canyon Tuff) were measured on spot sizes of 20, 15, 10, and 7 μm diameter. Laser fluence was increased from 3 to 6 J cm -2 with decreasing spot size to compensate partially for decreasing U and Pb signals. 91500 zircon was the calibration reference material. Raw count rate data were processed using Iolite version 3.63 software with the U-Pb common approach data reduction scheme and smoothed cubic spline DHF correction model. Samples were ablated for 30 seconds and results processed for the first 28, 15, 10, and 7 seconds of ablation (masking the initial 2 seconds) in order to assess the accuracy and precision of U-Pb ages as a function of ablation time. Measured 206 Pb/ 238 U ratios for the six zircon reference materials increase steadily with ablation time, reflecting DHF, but exhibit somewhat different patterns of increase for different zircons, producing the major source of uncertainty for the U-Pb ages. A secondary source of uncertainty is differences between the 206 Pb/ 238 U (normalized to their accepted values) for different zircons near the start of ablation, which may reflect matrix-dependent instrumental mass bias in the ICP. Nonetheless, processing data from only the first 10 to 15 seconds of ablation (50 to 75 laser pulses) restricts the extent of DHF and time-resolved Pb/U variations between different zircons to a sufficient degree to give concordant U-Pb ages on 20 to 7 μm spots that are accurate and precise to better than 1.4% using LA-ICP-single-collector-SF-MS instrumentation.

Original languageEnglish
Pages (from-to)180-192
Number of pages13
JournalJournal of analytical atomic spectrometry
Volume34
Issue number1
DOIs
StatePublished - Jan 2019

Fingerprint

Dive into the research topics of 'Accuracy and precision of U-Pb zircon geochronology at high spatial resolution (7-20 μm spots) by laser ablation-ICP-single-collector-sector-field-mass spectrometry'. Together they form a unique fingerprint.

Cite this