A test of dual readout with tiles for calorimetry

F. Bedeschi, A. Cardini, M. Cascella, G. Ciapetti, D. De Pedis, R. Ferrari, S. Franchino, G. Gaudio, P. Genova, J. Hauptman, L. La Rotonda, F. Lacava, S. Lee, M. Livan, E. Meoni, D. Pinci, A. Policicchio, F. Scuri, C. Voena, R. Wigmans

Research output: Contribution to journalArticlepeer-review

Abstract

A small detector (6 radiation lenghts in total) divided into two sections of four times lead-quartz-scintillator tiles, each with a separate readout for Čerenkov and scintillation light has been tested. The results for high energy muons and electrons are presented. The measured erenkov light yield for electrons is about 50 Č.p.e. per deposited GeV.

Original languageEnglish
Article numberC05009
JournalJournal of Instrumentation
Volume9
Issue number5
DOIs
StatePublished - May 1 2014

Keywords

  • Calorimeter methods
  • Calorimeters
  • Cherenkov and transition radiation