TY - GEN
T1 - A fall detection study on the sensors placement location and a rule-based multi-thresholds algorithm using both accelerometer and gyroscopes
AU - Jacob, Jerene
AU - Nguyen, Tam
AU - Lie, Donald Y.C.
AU - Zupancic, Steven
AU - Bishara, J.
AU - Dentino, Andrew
AU - Banister, Ron E.
PY - 2011
Y1 - 2011
N2 - Falls are dangerous among the elderly population and are a major health concern. Many investigators have reported the use of accelerometers for fall detection. In addition, the use of miniature gyroscopes has also been reported to be able to detect falls, but the effects of sensor placement on the back of a person have not been studied thoroughly. In this paper we present a simple solution for effective fall detection using both an accelerometer and two gyroscopes placed, as a single unit, on three different positions along the thoracic vertebrae (i.e., T-4, T-7, and T-10). Results indicated that T-10 was not a good location for the gyroscope placement for fall detection. However, both T-4 and T-7 were suitable, with the results for T-4 being slightly better. Using a simple rule-based multi-thresholds algorithm that utilizes the recorded resultant gravitational acceleration, angular change, angular velocity, and angular acceleration, we were able to successfully detect all 60 falls and differentiate between falls and activities of daily living (ADL) with no false positives on young volunteers. More testing data is needed, especially for backward falls, to test the robustness of our simple algorithm and to improve the sensor portability for future trial studies on geriatric populations.
AB - Falls are dangerous among the elderly population and are a major health concern. Many investigators have reported the use of accelerometers for fall detection. In addition, the use of miniature gyroscopes has also been reported to be able to detect falls, but the effects of sensor placement on the back of a person have not been studied thoroughly. In this paper we present a simple solution for effective fall detection using both an accelerometer and two gyroscopes placed, as a single unit, on three different positions along the thoracic vertebrae (i.e., T-4, T-7, and T-10). Results indicated that T-10 was not a good location for the gyroscope placement for fall detection. However, both T-4 and T-7 were suitable, with the results for T-4 being slightly better. Using a simple rule-based multi-thresholds algorithm that utilizes the recorded resultant gravitational acceleration, angular change, angular velocity, and angular acceleration, we were able to successfully detect all 60 falls and differentiate between falls and activities of daily living (ADL) with no false positives on young volunteers. More testing data is needed, especially for backward falls, to test the robustness of our simple algorithm and to improve the sensor portability for future trial studies on geriatric populations.
KW - T-4
KW - accelerometer
KW - activities of daily living (ADL)
KW - fall detection
KW - gyroscope
KW - sensor
UR - http://www.scopus.com/inward/record.url?scp=80053084427&partnerID=8YFLogxK
U2 - 10.1109/FUZZY.2011.6007744
DO - 10.1109/FUZZY.2011.6007744
M3 - Conference contribution
AN - SCOPUS:80053084427
SN - 9781424473175
T3 - IEEE International Conference on Fuzzy Systems
SP - 666
EP - 671
BT - FUZZ 2011 - 2011 IEEE International Conference on Fuzzy Systems - Proceedings
T2 - 2011 IEEE International Conference on Fuzzy Systems, FUZZ 2011
Y2 - 27 June 2011 through 30 June 2011
ER -